Language
1
1
Your Location:
Homepage
/
/
/
How to extend the service life of forklift batteries

How to extend the service life of forklift batteries

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2021-06-18
  • Views:0

(Summary description)During the charging process of the forklift battery, the battery will generate gas. The charging place should be well ventilated and there is no open flame around. At the same time, the oxygen and acid gas generated during the charging process will affect the surroundings. When charging, half open the battery filling hole (liquid filling cover) to avoid excessive electrolyte (dilute sulfuric acid) from flowing out.

An arc will occur when the charging plug is unplugged during charging. After the charger is closed, the plug can be unplugged. After charging, there is a lot of hydrogen around the battery, no open flame is allowed, and the cover on the battery should be opened for charging. It is better to charge the battery pack once every 1.5 months or 2 months.

Adding water: add distilled water according to the specified liquid level. Do not add too much distilled water to extend the interval of adding water. Adding too much water will cause leakage of electrolyte. Maintenance of terminals, wires, and covers: It is necessary to be professionally designated by the manufacturer Technicians can only clean: if it is not too dirty, you can wipe it with a damp cloth, if it is very dirty, remove the battery from the car, wash it with water and let it dry naturally.

Key points in the use of forklift batteries: Appearance: The dirty surface of the battery will cause leakage. The surface of the battery should be clean and dry at all times. Terminals, wires, and covers: It is necessary to check the junctions of the battery terminals and the junctions with the wires due to oxidation. Corrosion status, and check whether the cover is deformed and whether there is heat.

How to extend the service life of forklift batteries

(Summary description)During the charging process of the forklift battery, the battery will generate gas. The charging place should be well ventilated and there is no open flame around. At the same time, the oxygen and acid gas generated during the charging process will affect the surroundings. When charging, half open the battery filling hole (liquid filling cover) to avoid excessive electrolyte (dilute sulfuric acid) from flowing out.

An arc will occur when the charging plug is unplugged during charging. After the charger is closed, the plug can be unplugged. After charging, there is a lot of hydrogen around the battery, no open flame is allowed, and the cover on the battery should be opened for charging. It is better to charge the battery pack once every 1.5 months or 2 months.

Adding water: add distilled water according to the specified liquid level. Do not add too much distilled water to extend the interval of adding water. Adding too much water will cause leakage of electrolyte. Maintenance of terminals, wires, and covers: It is necessary to be professionally designated by the manufacturer Technicians can only clean: if it is not too dirty, you can wipe it with a damp cloth, if it is very dirty, remove the battery from the car, wash it with water and let it dry naturally.

Key points in the use of forklift batteries: Appearance: The dirty surface of the battery will cause leakage. The surface of the battery should be clean and dry at all times. Terminals, wires, and covers: It is necessary to check the junctions of the battery terminals and the junctions with the wires due to oxidation. Corrosion status, and check whether the cover is deformed and whether there is heat.

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2021-06-18
  • Views:0
Information
During the charging process of the forklift battery, the battery will generate gas. The charging place should be well ventilated and there is no open flame around. At the same time, the oxygen and acid gas generated during the charging process will affect the surroundings. When charging, half open the battery filling hole (liquid filling cover) to avoid excessive electrolyte (dilute sulfuric acid) from flowing out.
 
An arc will occur when the charging plug is unplugged during charging. After the charger is closed, the plug can be unplugged. After charging, there is a lot of hydrogen around the battery, no open flame is allowed, and the cover on the battery should be opened for charging. It is better to charge the battery pack once every 1.5 months or 2 months.
 
Adding water: add distilled water according to the specified liquid level. Do not add too much distilled water to extend the interval of adding water. Adding too much water will cause leakage of electrolyte. Maintenance of terminals, wires, and covers: It is necessary to be professionally designated by the manufacturer Technicians can only clean: if it is not too dirty, you can wipe it with a damp cloth, if it is very dirty, remove the battery from the car, wash it with water and let it dry naturally.
 
Key points in the use of forklift batteries: Appearance: The dirty surface of the battery will cause leakage. The surface of the battery should be clean and dry at all times. Terminals, wires, and covers: It is necessary to check the junctions of the battery terminals and the junctions with the wires due to oxidation. Corrosion status, and check whether the cover is deformed and whether there is heat.

Scan the QR code to read on your phone

Related News

What are the ways to extend the service life of the battery pack 2021-05-28 15:01:00
We often use battery packs in our daily lives, and if we can’t prolong its service life, it will not only waste our money, but it is also very detrimental to environmental protection. In fact, as long as any battery is carefully maintained, its use can be extended, which is also very beneficial to us. Here are some ways to extend the service life, I believe it will definitely help you. Method one is to charge and discharge in time. If you don't use the battery often, you can choose to charge and discharge it completely every one to two months, which can also keep the battery active. Only in this way can the chemicals in the battery ensure its normal operation, and it is also a simple way to prolong its service life. Even if you often use the battery, you still have to perform such complete discharge and charging on time to ensure the normal use of the battery. Method two, do not frequently use meaninglessly. Regardless of where your battery pack is to be used, you must pay attention to energy conservation. This is not only for environmental protection, but also helps us save money. Moreover, if a battery is used frequently, it will also shorten its lifespan. As long as it is not necessary to use, it is better to reduce the possibility of ordinary use. If you really want to use ordinary, but also pay attention to its maintenance. Method three, pay attention to the battery status. Although what we are doing is to extend its service life, if the battery has already had a problem, don't use it again. Especially the batteries used in some children's toys, we also need to check them in time. Although the battery is not high, it still has a certain impact on the child. If you can do the above, you will be able to increase the service life of the battery. Nowadays, there are more places where batteries are used. If you want to save energy and protect the environment, you must start with the small things around you. Energy saving at home is also very important, and protecting the battery can also save us a lot of money and reduce the cost of living. So everyone must protect the battery and don’t sloppy every detail of life.
Precautions for the installation of battery forklift batteries, factors affecting the service life of battery forklift batteries 2021-05-28 14:59:00
1) The installer (or engineering team) of the battery forklift battery receives the installation task instruction, prepares relevant materials (such as the battery installation of various manufacturers, record sheets, etc.) and a full set of installation tools (including multimeters, etc.), and confirms the start date of the project And the progress of the project. 2) The installer (or engineering team) should bring a small amount of system spare parts (such as screws, etc.) to the installation site, obtain a detailed installation project schedule, and discuss project details (such as installation methods, load-bearing conditions, etc.). 3) Before starting the installation project, the installer (or engineering team) should be organized to conduct training, introduce the precautions during the installation process, battery usage and maintenance precautions, and pay attention to safety during the installation process. 4) The installer (or engineering team) conducts the unpacking inspection of the battery and the inventory of the accessories. The packing list should be signed and taken back by the supervisor. The battery installation system diagram, installation manual and other documents in the accessory box should be received, and the installation project is pending After the end, it will be kept by the technical staff of the communication company. 5) In accordance with the construction drawings, check whether the battery is placed in the equipment room reasonably, whether it has reserved maintenance space, whether it is kept at a distance of more than 0.5 meters from the heat source and the place that may generate sparks (such as fuse box, etc.), and whether it is placed Under the air conditioner, if it does not meet the requirements, you should first ask the engineering department of the communications company whether to modify it, and there must be a memorandum for the modification. 6) The system diagram of unpacking the battery should be installed strictly in accordance with the system diagram of the battery. The installation of any missing system components (including the pasting of battery cell numbers) is not allowed, and all system components (spare parts) should be installed in accordance with the installation diagram. The specified models and specifications are exactly the same. 7) Installation. Since the battery is already charged, care must be taken to prevent short circuits. All installation tools must be wrapped with insulating tape. 8) Before installing the connecting strip, wipe off the dust on the battery pole, shell and steel frame with a clean linen cloth, especially to ensure that the dust on the pole is wiped clean. The unit number must be attached firmly. 9) After installation, check whether all screws are tightened one by one. A special person should be appointed for inspection, and a special person is responsible to ensure that all screws are in a tightened state. 10) After the installation inspection, measure and record the open circuit voltage of all battery cells and the total voltage of the battery pack, and fill in the installation statistics table (or other similar installation tables). 11) If there is no mains connection after installation, disconnect the battery, switching power supply and microwave equipment. If the connection between the device and the battery cannot be disconnected for some reason (in principle, it is not allowed, especially for a long time connection is not allowed), both sets of batteries should be connected at the same time, and only one set of batteries is not allowed. At the same time, record the start time of the connection and the power consumption current of the device, and make a record. Regardless of whether this connection has been made, the battery pack must be recharged before it is officially opened. The time for recharging is that the cell voltage is 2.35V/piece, and it is charged for 12 hours. Otherwise, it will bring great harm to the normal use of the battery in the future. 12) Before connecting the battery to the switching power supply, carefully check whether the setting of the switching power supply is correct (refer to the switching power supply setting parameter table) to ensure that the setting is correct. 13) After installation and debugging, fill in the relevant forms as required, check the appearance of the battery and record it, and check whether each connection screw is tightened to ensure that the battery is shock-proof, anti-skid and reliable connection between the batteries. Measure and record the float voltage of each single battery, and ask the technical staff of the communication company to sign and approve.
Daily maintenance method of battery 2021-05-28 14:56:00
⑴ Long life The pole plate made of special lead-calcium alloy with good corrosion resistance can have a long floating life; Special colloidal electro-hydraulic is used to increase the acid content of the battery, prevent electro-hydraulic delamination, prevent short circuit of the plate branch crystals, and ensure a long battery life. Gel battery is based on the valve-regulated sealed lead-acid battery technology to achieve a long life. So the design life of 12V series gel battery is 6-8 years (25℃); the design life of 2V series gel battery is 10-15 years (25℃). ⑵ Less self-discharge A grid made of a special lead-calcium alloy is used to limit the self-discharge to a minimum and can be stored for a long time. ⑶ Easy to maintain Since most of the oxygen generated inside the battery is absorbed by the cathode plate and reduced to electrolyte during floating charging, there is basically no reduction in electrolyte, so there is no need to measure the specific gravity and replenishment of electrolyte like ordinary batteries. ⑷ Simple installation The battery can be installed vertically or on the side, and there is no danger of electro-hydraulic leakage, and the battery will not produce acid mist during normal charging. Therefore, the battery can be installed in the office or supporting equipment room without the need to build a special battery room, which reduces the project cost. ⑸ High security To prevent excessive gas generation, the battery is equipped with a safety valve. In addition, it is equipped with an explosion-proof filter, which prevents fire from reaching the inside of the battery even if there is a spark approaching in the structure. ⑹ Easy to use The battery is fully charged before leaving the factory, and the user can install and put it into use after receiving the battery.
What should be paid attention to when using electric forklift battery 2021-06-18 14:03:00
Electric forklift batteries, also known as batteries, have traction type and start type. Internal combustion forklifts use starter electric forklift batteries, while electric forklifts use traction electric forklift batteries. Electric forklift batteries are divided into acidic and alkaline. Generally, internal combustion vehicles use lead-acid electric forklift batteries. The nominal voltage of a single cell battery is 2 volts, which are connected in series to form 12 volts. The electrolyte specific gravity of the electric forklift battery is 1.28 at a standard temperature of 15 degrees Celsius. When the cell voltage of the electric forklift battery drops below 1.5 volts, or the specific gravity of the electrolyte drops to 1.17, it indicates that the electric forklift battery is discharged and must be charged in time. The electrolyte level of the battery of an electric forklift must be 10-15 mm higher than the electrode plate. If the level is too low, distilled water must be added in time, and other liquids must not be added. The battery of an electric forklift in use should generally be charged outside the vehicle every quarter. The charging current is the capacity of the battery of the electric forklift divided by 10, and the charging time is about ten hours. Electric forklift batteries that have not been used for a long time should be fully charged and placed in a cool and dry place, and recharged every month or so.
Previous page
1
2
3

Contact Us

Sales Hotline: 19962636595
Contact
  • Joyzoom Follow Us

Copyright © Jiangsu Joyzoom Power Co., Ltd.   All Rights Reserved    Power by :www.300.cn